Marginal leakage of temporary restoration after intraradicular post preparation with or without waterproofing
DOI:
https://doi.org/10.14295/bds.2017.v20i2.1411Abstract
Objective: This study evaluated the leakage volume of 1% Rhodamine B which received or not an internal waterproofing material. The hypothesis is that the waterproofing reduces microleakage. Material and Methods: Forty-two human teeth were selected for this study. After access, preparation, and filling of root canals, the teeth were divided into 3 groups: GI – sealed with Cimpat Blanc®, without intraradicular post/core preparation; GII - sealed with Cimpat Blanc®, with intraradicular post/core preparation, and GIII – sealed with Cimpat Blanc®, with intraradicular post/core preparation and internal waterproofing material with ethyl cyanoacrylate. T-test was used to analyze difference between initial and final weight and there was difference (p < 0.05). To analyze infiltration of the colorant, the volume was the comparison variable. Results: Shapiro Wilk- test was applied and showed normal distribution of the variables. ANOVA (p = 0.0013 / p<5%) applied and determined a statistical difference between the groups. When comparing the groups together, GIII show the smallest leakage rate when compared with the other groups, being statistically different (Tukey test - p < 0.5). Conclusion: In endodontically treated teeth receiving temporary restoration, the use of ethyl cyanoacrylate as internal waterproofing material is effective in preventing microleakage.
Keywords
Dental leakage; Endodontics; Dental restoration, temporary; Coloring agents.
Downloads
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.