Diagnosis of a horizontal root fracture during retreatment of a maxillary canine utilizing an electronic apex locator and monitoring with CBCT: a case report
DOI:
https://doi.org/10.14295/bds.2013.v16i4.923Abstract
Introduction: The aim of this case report is todemonstrate the retreatment of a maxillary caninediagnosed with a horizontal root fracture utilizingan electronic apex locator and monitored with conebeam computed tomography. Case Report: A 35year old African American male was referred for rootcanal retreatment of a maxillary right canine prior toprosthetic rehabilitation. Following removal of guttapercha, an apex locator was utilized to determine thelength of the root canal. After a more comprehensivedental history, the patient confirmed a previouslyunreported history of dental trauma at this time,leading to the suspicion of a horizontal root fracture.Clinical microscopy detected a connective tissue in theapical third of the root canal and multiple periapicaland occlusal radiographs enhanced visualizationof a horizontal root fracture. The coronal segmentwas filled with an MTA apical plug and the apicalsegment remained stable. A recall after 1.5 yearswas performed with CBCT, which showed no apicalradiolucency. Discussion: The present case reportreinforces the precept that detailed dental history andcareful observation of radiographs are critical factorsfor obtaining an accurate diagnosis. Fundamentaladjuncts, such as microscopy, apex locators andCBCT imaging, can potentially aid in the diagnosisand the subsequent treatment plan of horizontal rootfracture.
Keywords
Cone-beam computed tomography; Apex locator Cuspid; Radiography; horizontal root fracture.
Downloads
Additional Files
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.