Volumetric measurement of sleep bruxism-like indentations on acrylic surface using intraoral scanner and inlay wax
DOI:
https://doi.org/10.4322/bds.2024.e4394Abstract
Objective: This in vitro study introduced methods to measure the volume of sleep bruxism-like indentations to be used in the evaluation of bruxing intensity. Material and Methods: Indentations of different sizes and depths were created on seven clear heat-cured acrylic blocks. The volume of all indentations was first measured by a profilometer as the gold standard, then by scanning the negative replicate of the indentations obtained from polyvinyl siloxane impressions both with double impression technique (IOSD) and putty silicone only (IOSP), using an intraoral scanner, and lastly by weighing the blue inlay wax used to fill the indentation. Agreements between the intraoral scanning and blue inlay wax methods compared to the profilometer were tested using ICC. Results: ICCs between IOSD, IOSP, inlay wax and the profilometer were 0.963, 0.950, and 0.999 respectively. The average volumetric error tended to be greater with IOSD (30.51±8.34 %) and IOSP (35.68±10.29 %) compared to that of blue inlay wax (24.87±10.29 %). Blue inlay wax was apparently superior to IOSD and IOSP in quantifying small and deep indentations. Conclusion: Both intraoral scanner and blue inlay wax had high agreement in volumetric measurement of acrylic indentations while the wax method performed the best. These methods could be used to measure the amount of wear on occlusal splints.
KEYWORDS
Intraoral scanner; Occlusal wear; Occlusal splints; Polyvinyl siloxane; Sleep bruxism.
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.