Bone Density and Implant Stability in using Advanced Platelet Rich Fibrin in Immediately Loaded- Implant Assisted Mandibular Overdentures
DOI:
https://doi.org/10.4322/bds.2023.e3987Abstract
Objective: The aim of this study is to determine the effect of Advanced Platelet-Rich Fibrin on bone density and implant stability in immediately loaded- implant-assisted mandibular overdentures (Split-mouth study). Material and Methods: Ten completely edentulous patients received two implants in the mandibular canine region and locator attachments were used to retain immediately loaded- implant mandibular overdentures. Each patient served in two Groups, one Group for each side. One side of the mandible received an implant with topical application of Advanced Platelet-Rich Fibrin in the implant osteotomy site (Group I) and the other site received an implant without application of Advanced platelet-rich fibrin (Group II). Each patient was examined clinically for implant stability using Osstell Mentor device and radiographically by ultra-low dose CT scan to measure bone density around the implant at baseline, three, six months, and one year. Results: There were no statistically significant differences (P>.05) in bone density and implant stability among the studied Groups during one year follow-up period. Conclusion: Advanced Platelet-Rich Fibrin has no effect on bone density and implant stability in immediately loaded implant-assisted mandibular overdenture.
KEYWORDS
Advanced platelet-rich fibrin; Bone density; Immediately loaded implant; Implant stability; Locator attachment; Mandibular overdentures.
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.