Influence of fluoride-releasing materials in the inhibition of enamel and dentin demineralization around restorations
DOI:
https://doi.org/10.4322/bds.2022.e3505Abstract
Objective: The aim was to evaluate the influence of fluoride-releasing restorative materials in enamel and dentin
microhardness. Material and Methods: 40 blocks (5x5x3 mm) from cervical third of human molars received a cavity
preparation between the enamel and dentin, and the restorations were subjected to in vitro caries model. Specimens
were randomly restored with (n=10): conventional glass ionomer cement (Ketac Cem, 3M ESPE); polyacid-modified
composite resin (Ionoseal, VOCO); resin-modified glass ionomer cement (Ionofast, Biodinâmica); or microhybrid
composite resin (Filtek Z250, 3M ESPE). The specimens were sectioned longitudinally and enamel and dentin
Knoop microhardness were determined at different distances from the restorative material (100, 200 and 300 um)
and depth of surface (20, 40 and 60 um). The data were submitted to three-way repeated measures ANOVA and
Tukey´s test (a=0.05). Results: For enamel, the double interactions between material x distance and material x
depth were statistically significant. In all depths and distances, the highest values of enamel microhardness were
observed for Ketac Cem. In dentin, the materials differed statistically from each other, and Ionoseal obtained higher
microhardness values than those found in Ionofast. Conclusion: Conventional glass ionomer cement is more effective
in preventing enamel demineralization around restoration followed by the polyacid-modified composite resin. In
dentin, the polyacid-modified composite resin obtained better performance than resin-modified glass ionomer cement.
KEYWORDS
Compomers; Dental caries; Glass ionomer cements; Hardness tests; Composite Resins.
Downloads
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.