Influence of composite resin volume and C-factor on the polymerization shrinkage stress
DOI:
https://doi.org/10.14295/bds.2016.v19i2.1257Resumo
Objective: Composite polymerization shrinkage
stress is an inherent process of chemical and light
composite resin activation. Consequently, this fact has
been associated to potential clinical problems. The
aim of the present in vitro study was to evaluate the
volume and C-factor influence on chemical and lightcuring
composite resin polymerization shrinkage
stress, using a non-rigid method that thereby provides
lower stress values, causing a minimal deflection in
load cell. Materials and Methods: The contraction
forces of the Z-250 and Concise composite resins
during polymerization were recorded in an UTM in
two experiments. In the first experiment, the Z-250
composite was inserted beetwen two rectangular
steel plates (6.0 x 2.0 mm), varyng the resin volumes
and C-factors, in a single increment, polymerized for
20 s and the forces generated were recorded for 120
s. In the second experiment, a pair of rectangular steel
plates (3x2mm) and two square steel plates (2x2mm),
with varied heights (2; 3 mm, respectively), were
used to determine the C-factor (0.6; 0.3) influence.
Results: The polymerized Z-250 results showed that
the volume variations, independent of the C-factor,
had a direct influence on the shrinkage stress,
different from the Concise, which was influenced by
the C-factor. Conclusion: The present study showed
that a higher volume of composite resins determines
an increase in the shrinkage stress of light-curing
composites.
Keywords
C-factor. Composite resin. Polymerization. Shrinkage
stress.
Downloads
Downloads
Arquivos adicionais
Publicado
Como Citar
Edição
Seção
Licença
TRANSFERÊNCIA DE DIREITOS AUTORAIS E DECLARAÇÃO DE RESPONSABILIDADE
Toda a propriedade de direitos autorais do artigo "____________________________________________________________________" é transferido do autor(es) para a CIÊNCIA ODONTOLÓGICA BRASILEIRA, no caso do trabalho ser publicado. O artigo não foi publicado em outro lugar e não foi submetido simultaneamente para publicação em outra revista.
Vimos por meio deste, atestar que trabalho é original e não apresenta dados manipulados, fraude ou plágio. Fizemos contribuição científica significativa para o estudo e estamos cientes dos dados apresentados e de acordo com a versão final do artigo. Assumimos total responsabilidade pelos aspectos éticos do estudo.
Este texto deve ser impresso e assinado por todos os autores. A versão digitalizada deverá ser apresentada como arquivo suplementar durante o processo de submissão.