Bond strength of dual – cured resin cements to a glass infiltrated alumina ceramic
DOI:
https://doi.org/10.14295/bds.2006.v9i2.479Resumo
The present study evaluated the union resistance among the surface of the ceramic In Ceram Alumina® (Vita Zahnfabrik, Bad-Säckingen, Germany) and two different types of resin cements (Panavia F, Kuraray® e Relyx, 3M®). Six ceramics blocks were made with dimensions of 6x6x5mm following the technical guide lines wich were duplicated in composite resin (W3D MASTER®). One of the faces of the ceramic block (6mmx5mm) was sandblasted with the Rocatec system® and cemented with the two different cements under constant load of 750g to the correspondents faces composite blocks. After the storage of the samples (seven days in distilled water at 37º) each group formed by ceramic, cement and resin was split up in two axis X and Y and it were obtained specimens with adehive area of 1mm² ± 0,1. Two groups (n=27) were obtained: PanaviaF group and RelyX group. Each sample was fixed with cyanocrylate in an adapted device which was attached to a universal testing machine (EMIC) and then subjected to tensile forces at a crosshead of 0.5 mm/min and load cell of 10kgf. The results showed that the medium values of rupture (MPa) for the PanaviaF group (median=30.98 ± standart deviation=5.43) are statistically different comparing to RelyX group (median 12.48 ± standart deviation 3.54) (p-value=0.,001). The conclusion of this study was that the Panavia F had better adhesive resistance than RelyX. All fractures analyzed occurred at the adhesive zone, with no findings of cohesive fracture of the porcelain.
Downloads
Downloads
Publicado
Como Citar
Edição
Seção
Licença
TRANSFERÊNCIA DE DIREITOS AUTORAIS E DECLARAÇÃO DE RESPONSABILIDADE
Toda a propriedade de direitos autorais do artigo "____________________________________________________________________" é transferido do autor(es) para a CIÊNCIA ODONTOLÓGICA BRASILEIRA, no caso do trabalho ser publicado. O artigo não foi publicado em outro lugar e não foi submetido simultaneamente para publicação em outra revista.
Vimos por meio deste, atestar que trabalho é original e não apresenta dados manipulados, fraude ou plágio. Fizemos contribuição científica significativa para o estudo e estamos cientes dos dados apresentados e de acordo com a versão final do artigo. Assumimos total responsabilidade pelos aspectos éticos do estudo.
Este texto deve ser impresso e assinado por todos os autores. A versão digitalizada deverá ser apresentada como arquivo suplementar durante o processo de submissão.