Surface roughness of indirect composites using different polishing systems
DOI:
https://doi.org/10.14295/bds.2013.v16i4.927Abstract
Objective: The aim of this study was to evaluatethe surface roughness of indirect composites afterpolishing with aluminum oxide (Al2O3) discs. Materialand Methods: One-hundred and eighty specimenswere confectioned with 6 indirect composites using aprefabricated matrix, resulting in six groups (n-30):Group SO - Solidex, Group SI - Signum, Group SF- Sinfony, Group OP - Opallis; Group RE - Resilab,Group EP - Epricord, Group AD - Adoro. Each groupwas divided into three subgroups according to thepolishing (n-10): Subgroup C (Control) - withoutpolishing (polyester strip); Subgroup S - polishingwith Sof-Lex discs; Subgroup T - polishing with TDVdiscs. The surface roughness was measured with aprofilometer. Results: The results were analyzed byANOVA and Tukey tests (5%), resulting in p = 0.00.The mean values (±standard-deviation) measured inRa (?m) for each Group/Subgroup were: RE/C - 0.14(± 0.14) a; EP/C - 0.18 (± 0.46) ab; SO/C - 0.24 (±0.22) abc; SF/S - 0.24 (± 0.17) abc; SF/C - 0.26 (±2.54)abc; SI/C - 0.30 (± 0.34)abcd; SO/T - 0.33(±0.42) abcd; AD/S - 0.34(± 0.88)abcd; AD/C - 0.37(±0.60)ab; SI/S - 0.37(± 1.39)bcd; SO/S - 0.43(± 0.26)cd; EP/S – 0.44 (± 1.02) cd; RE/S - 0.54(±2.02) de;SI/T - 0.65(± 0.88)ef; RE/T - 0.83 (± 0.54) fg; SF/T- 0.85 (± 0.21) fg; AD/T - 0.88 (± 1.74) fg; EP/T- 0.91(± 0.89) g. Conclusion: It is concluded thatpolyester strip resulted in significantly lowest surfaceroughness; polishing with TDV discs resulted insignificantly higher surface roughness compared toSof-Lex discs and that the surface roughness resultsdepend on the composite tested.
Keywords
Composite resins; Dental polishing; Biofilms.
Downloads
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF | Word)
All manuscript's copyright ownership of the article "____________________________________________________________________" is transferred from the author(s) to the BRAZILIAN DENTAL SCIENCE, in the event the work is published. The manuscript has not been published elsewhere and that it has not been submitted simultaneously for publication elsewhere.
We hereby attest the study is original and does not present manipulated data, fraud or plagiarism. We made significant scientific contribution to the study and we are aware of the presented data and in agreement with the final version of the manuscript. We assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.